DIAGNOSTICS
INFRARED TERMOGRAPHY - COMPUTERIZED ANALYSIS

 

AREA
PLASTERED OR COVERED EXTERNL SURFACES

APPLICATION TECHNIQUE
Termo-visual IR instruments are used to check the suface temps' distribution following a thermal stress.The thermal stress is obtained by solar irradiation or through spontaneous night-day thermal gradient use.

OBTAINABLE RESULTS
Computerized IR image processing with applicatory software and critic-defect checking maps.

critical relief:

termal image IR

RELATED DIAGNOSTICS
- Log-collected sample lab tests
- Magnetometry
- Preliminary photografic and visual analysis
- Endoscopy

COSTS
- Punctual intervention Euro 1.291,00 each
- Exended intervention Euro 2,58 - 7,75 /mq
  DETECTABLE DATA
Architectural survey:
wall material marking out separating stony and lateritious materials; plugging; fuel and technologic installations survey; undersurface wooden, metallic, or ferro-concrete elements check.
Pathological aspects:
plaster and cover discohesion; repaid structural damages; dampness soaking (possible origin location); "thermal bridges".

real image
real image

SURVEY
- Surface quantification
- Walls location and orientation
- Work site max dimensions exstimation
- Accessibility and use of the around the building area
- Scale cartographic documentation
- Physical charachteristics of the surface
- Historical references

The thermography is executed on external side plastered wall hangings to locate and survey concealed architectural elements, wall structures, cracks and dampness. Data are returned on graphic documentation previously set by the purchaser. Every work is carried out with portable IR sensible instruments, using natural thermal gradient (sunrays and shade) on analysed elements. Works follow UNI 9252 and ISO 6781 rule standards, data returning is accompanied by anomaly and decay photographic certification following UNI 9124 rule standards, IR images, in place collected IR images computerized processing, final detailed technical report.
   